AirTrap® Calibration Kit – Factory-Verified Flow Check for 15 l/min Pumps
AirTrap® Calibration Kit – Factory-Verified Flow Check for 15 l/min Pumps
VAT calculated at checkout
A verified flow rate is the line in your report that makes the spore count defensible.
The flow rate of the pump sets the volume of air sampled – and with it the spores/m³ in the lab result. A pump running off target over- or understates the concentration. The AirTrap® Calibration Kit lets you verify 15 l/min on site in under a minute: open the case, connect the kit to the AirTrap® XL cassette, read the float. Pre-assembled, factory-verified, no adapters to hunt for and no recurring calibration to schedule.
What makes it different
Unlike a generic flow meter, the kit is a complete, factory-verified assembly with an AirTrap® inlet adapter developed by Apacor. It connects directly to the cassette – no extra tubing, adapters or pump-specific hardware.
What you get
Fully pre-assembled AirTrap® Calibration Kit:
- 1× Dwyer Series VF Visi-Float® flow meter (rotameter)
- 1× HDPE elbow, black (1/8" NPT × 1/4" barb)
- 1× clear PVC tubing (50 mm)
- 1× Apacor AirTrap® inlet adapter
Why this kit
- Factory-verified – no recurring calibration of the kit, no annual service cost, no downtime
- No adapters needed – the integrated inlet adapter connects directly to the sampling cassette
- Universal – works with all standard 15 l/min air sampling pumps
- Low total cost of ownership – one purchase, no follow-on costs over its service life
- Field-proof – built for repeated use in rough conditions
- Fast, repeatable setup – one simple workflow, minimal set-up time
- Direct reading – Visi-Float® acrylic body with engraved scale, no batteries, no display
Use in 5 steps
- Prepare the pump: pump off; check tubing for cracks, kinks or dirt.
- Connect the kit to the AirTrap® sampling cassette; make sure the connections are airtight.
- Start the pump and set the target flow (15 l/min).
- Verify: let the pump stabilise for a few seconds, read the flow on the scale, adjust if needed.
- Finish: pump off, remove the kit – your pump is verified and ready.
Good practice
- Store the kit dry and dust-free
- Keep the tubing clean and dry to maintain accuracy
- Verify the flow before every sampling campaign
Why pump calibration matters
The flow rate determines the actual volume of air sampled and therefore the quantitative value of the lab result. For expert reports, remediation clearance and insurance cases a documented pump calibration is often a requirement; an on-site check before every campaign is good professional practice – record the value in your sampling log. Method and standards: Indoor air measurement · Pump instructions.
Technical data
- Type: variable-area flow meter (rotameter) with clear Visi-Float® acrylic body
- Range: 5–25 l/min (target 15 l/min with margin)
- Reading: direct mechanical reading of the float position
- Power: none required – purely mechanical
- Calibration: factory-verified, no recurring calibration required
- Connection: integrated AirTrap® inlet adapter (1/8" NPT × 1/4" barb)
Compatibility
Optimised for AirTrap® XL sampling cassettes and the Sporecyte™ air sampling pump (both available separately); compatible with all 15 l/min air sampling pumps.
Delivery and price
Free delivery within the EU. Prices include VAT.